Measurement & TestingLesson 8: How to Use a Digital Multimeter
Module 5: Measurement

Lesson 8: How to Use a Digital Multimeter

How to use a multimeter safely: measure DC voltage, current, resistance and continuity on a virtual meter, with correct probe placement and socket selection.

  • About 30 minutes
  • 7 questions
  • 1 hands-on activity

Builds on Lesson 7: Electrical Power and Energy

In this lesson you’ll learn

  • What a multimeter does
  • Measuring DC voltage in parallel
  • Measuring current in series
  • Measuring resistance on a de-energised circuit
  • Continuity testing
  • Choosing the right setting and socket safely
Lesson summary
  • A multimeter measures voltage (V), current (A) and resistance (Ω), and can test continuity.
  • Voltage is measured in parallel: put the probes across the component, either side of it.
  • Current is measured in series: break the circuit and let the current flow through the meter.
  • For current the red lead goes in the A (10 A) socket. Then the meter is almost a wire, so never put it across a voltage.
  • Resistance and continuity must only be measured with the circuit de-energised.
  • OL means “over limit”: on resistance, an open circuit with no path between the probes.

Lesson notes: How to Use a Digital Multimeter

A written version of this lesson. The hands-on simulators are in the lesson itself.

One meter, several jobs

A digital multimeter combines a voltmeter, an ammeter and an ohmmeter. A dial chooses what it measures. Two leads connect it to the circuit:

  • The black lead always goes in COM (common).
  • The red lead goes in VΩ for volts, ohms and continuity, or in 10 A for current.

Every reading on this virtual meter is calculated from the simulated circuit. Try touching the probes on A and F.

Key idea: Choose the setting, check the socket, then place the probes. In that order, every time.

Measuring voltage: in parallel

Voltage is a difference between two points, so the meter goes across the component: one probe each side, in parallel with it. Nothing needs disconnecting.

Measure across the lamp (E and F), then across R1 (D and E). Then swap the probes over and see the sign change.

Key idea: A voltmeter has a very high resistance, so connecting it in parallel barely changes the circuit. A minus sign just means the probes are the other way round.

Measuring current: in series

Current has to flow through the meter, so the meter goes in series: open the circuit and let the meter bridge the gap.

  1. Set the dial to A and move the red lead to the 10 A socket.
  2. Remove the test link (tap it, or use the button).
  3. Put the red probe on C and the black probe on D.

Key idea: On its current range the meter has almost no resistance, so it doesn’t disturb the current it measures.

The danger: an ammeter across a battery

With the red lead in the 10 A socket, the meter is almost a wire. Put the probes across a voltage source and you make a short circuit through the meter.

Here it is safe to try: put the probes on A and F with the meter set to current. A real meter’s fuse should blow; on a large battery, a meter with the wrong fuse or none can be destroyed, spark or even explode in your hand.

Key idea: Before measuring voltage, always check the red lead is back in VΩ. Leaving it in the A socket is one of the most common, and dangerous, multimeter mistakes.

Measuring resistance: power off

On the Ω setting, the meter sends its own small test current through the component and calculates R = V ÷ I.

Another voltage in the circuit would ruin the reading and can damage the meter, so resistance is only ever measured on a de-energised circuit. Try measuring R1 (D and E) with the battery connected, then disconnect it.

Key idea: Isolate first. Real meters also read every path between the probes, so for an accurate value, disconnect at least one end of the component.

Continuity: is there a path?

The continuity setting beeps when the resistance between the probes is low (below about 30 Ω on many meters). It’s a quick yes/no check for broken wires, switches and fuses.

With the battery disconnected, test across the fuse (A and B). Then test across the open switch, or the removed link.

Key idea: Beep: a continuous path. OL: no path (open circuit). Again, only on a de-energised circuit.

No experience needed. Answer as you go; you can always try again.